Extron electronic MVX 88 Series ユーザーズマニュアル

ページ / 84
Operation, cont’d
MVX 44 / 48 / 84 / 88 VGA Matrix Switchers • Operation
3-24
PRELIMINAR
Y
Front panel security lockout (Executive mode)
The MVX Series switchers have a front panel security lockout feature (Executive 
mode) that limits the operation of the switcher from the front panel and optional IR 
remote control.  When the switcher is locked, the Enter button, I/O button 
(video, audio, or video and audio selection), and all of the front panel audio gain 
and attenuation functions are disabled.  The front panel input and output buttons 
continue to allow ties to be viewed, but ties cannot be created.
The front panel security lockout also disables the IR remote sensor to lock out 
remote control functions.
Toggle the front panel lockout on and off by pressing and holding the Enter and 
Preset buttons for approximately 2 seconds (figure 3-40).
PRESET
ENTER
PRESET
2 seconds
Press and 
hold the
Enter and Preset buttons.
The Preset LED 
flashes twice to indicate
that the front panel lockout has toggled on or off.
Release the Enter and Preset buttons.
Figure 3-40 — Toggle front panel lockout on or off
Clearing all ties and presets
To clear all ties and saved presets, press and hold the Preset button on the front 
panel while applying AC power (figure 3-41).  Continue to hold the Preset button 
until all LEDs light and then release the Preset button.  The power up sequence 
completes:
• All LEDs turn off then turn on and off from left to right.
• The Video and Audio LEDs turn on.
• All other LED remain off.
Power
PRESET
PRESET
I/O
AUD
AUDIO SETUP
PRESET
VID
+dB
-dB
1
1
Press and 
hold the Preset button while
you apply power to the switcher.
The switcher continues the power up process.
Release the Preset button.
The switcher lights 
all of the LEDs.
Figure 3-41 — Clear all ties and presets