Extron electronic MAV 48 ユーザーズマニュアル
3-23
MAV 44 / 48 / 84 / 88 Matrix Switchers • Operation
Resetting audio gain — single input
Reset a specified input’s audio gain or attenuation to the factory default (-12 dB for
captive screw audio connector [A] models, 0 dB for RCA audio connector [A RCA]
models) as follows:
captive screw audio connector [A] models, 0 dB for RCA audio connector [A RCA]
models) as follows:
1
.
Press and hold the Audio Setup (I/O) button for approximately 2 seconds
until the Audio Setup LED lights (figure 3-36).
until the Audio Setup LED lights (figure 3-36).
AUDIO SETUP
AUDIO SETUP
The LED lights to indicate Audio Setup mode.
Release the Audio Setup button.
2 seconds
Press and hold the button.
Figure 3-36 — Select Audio Setup mode
2
.
Press and release the Input 5 button (figure 3-37).
6
5
4
INPUTS
2
1
4
3
OUTPUTS
+dB
- dB
= lit, = unlit
Press and release the Input 5 button.
The Input 5 LED lights to
indicate that input 5 is selected.
indicate that input 5 is selected.
The –dB LED
indicates a negative
(attenuation) level.
indicates a negative
(attenuation) level.
In this example, the LEDs indicate audio attenuation in the –1 dB to –5 dB range.
The Output 1, Output 2, and Output 3
LEDs display the input's audio level range.
LEDs display the input's audio level range.
Figure 3-37 — Select an input
3
.
Press and release the
and
buttons simultaneously (figure 3-38).
Simultaneously press and release the
button and button.
button and button.
AUDIO SETUP
The Audio Setup
LED blinks off
and then relights.
LED blinks off
and then relights.
Figure 3-38 — Reset the selected input level
4
.
If desired, reset other inputs’ audio levels by repeating steps 2 and 3.
After approximately 30 seconds of front panel inactivity, the switcher saves the
most recent input gain or attenuation levels and exits Audio Setup mode.
most recent input gain or attenuation levels and exits Audio Setup mode.