Siemens ERTEC200 ユーザーズマニュアル

ページ / 97
 
6.1  Address Assignment of EMIF Registers 
The EMIF registers are 32 bits in width. These registers can only be written to with double words. 
 
EMIF  
(Base Address 0x7000_0000) 
Register Name
 
Offset Address
 
Address Area
Access
 
Default
 
Description
 
Revision_Code_and 
_Status 
0x0000 
4 bytes 
0x00000100
Revision code and status register 
Async_Wait_Cycle 
_Config 
0x0004 
4 bytes 
W/R 
0x40000080
Async wait cycle config register 
SDRAM_Bank_ 
Config 
0x0008 
4 bytes 
W/R 
0x000020A0
SDRAM bank config register 
SDRAM_Refresh 
_Control 
0x000C 4 
bytes 
W/R 
0x00000190
Setting of refresh rate 
Indication for timeout 
Async_BANK0_ 
Config 
0x0010 4 
bytes 
W/R 
0x3FFFFFF2
Timing/data bus width for access 
via async. interface CS_PER0_N 
Async_BANK1_ 
Config 
0x0014 4 
bytes 
W/R 
0x3FFFFFF2
Timing/data bus width for access 
via async. interface CS_PER1_N 
Async_BANK2_ 
Config 
0x0018 4 
bytes 
W/R 
0x3FFFFFF2
Timing/data bus width for access 
via async. interface CS_PER2_N 
Async_BANK3_ 
Config 
0x001C 4 
bytes 
W/R 
0x3FFFFFF2
Timing/data bus width for access 
via async. interface CS_PER3_N 
Extended_Config 
0x0020 
4 bytes 
W/R 
0x03030000
Setting of additional functionalities
Table 19: Overview of EMIF Registers 
6.2  EMIF Register Description 
Revision Code and Status 
 
R     
Addr.: 0x7000_0000      Default: 0x0000_0100
 
Description 
Revision code and status register 
 
Bit No. 
Name 
Description 
31..16 Reserved 
Reserved 
15..8 MAJOR_REVISION 
01h 
7..0 MINOR_REVISION 
00h 
 
 
Async wait cycle config  
 
W/R    Addr.: 0x7000_0004      Default: 0x4000_0080
 
Description Async 
wait 
cycle config register 
 
Bit No. 
Name 
Description 
31 Reserved 
Reserved 
30 WP 
Wait 
polarity 
0: Wait if RDY_PER_N = 0 
1: Wait if RDY_PER_N = 1 
29..8 Reserved 
Reserved 
7..0 
MAX_EXT_WAIT 
This value multiplied by 16 is equivalent to the number of AHB clock cycles 
that the async. controller waits for RDY_PER_N before access is terminated 
with timeout IRQ. 
 
 
 
Copyright © Siemens AG 2007. All rights reserved.                  
70
             
ERTEC 200 Manual 
Technical data subject to change                                                                                                                                Version 1.1.0