Sun Microsystems 5602 ユーザーズマニュアル

ページ / 324
A – Command Line Interface
Test Command
59097-01 A
A-121
0
The online loopback (node-to-node) test requires that port be online and 
connected to a remote device. To run the online loopback test, do the following:
1.
To start an admin session, enter the following command and press the Enter 
key.
admin start
2.
To run the online loopback test, enter the following command and press the 
Enter key. 
test port online
3.
A series of test parameters are displayed on the screen. Press the Enter key 
to accept each default parameter value, or type a new value for each 
parameter and press the Enter key. The TestLength parameter is the 
number of frames sent, the FrameSize (256 byte maximum in some cases) 
parameter is the number of bytes in each frame, and the DataPattern 
parameter is the pattern in the payload. Before running the test, make sure 
that the device attached to the port can handle the test parameters.
SANbox Manager (admin) #> test port online
A list of attributes with formatting and current values will 
follow. Enter a new value or simply press the ENTER key to 
accept the default value. If you wish to terminate this 
process before reaching the end of the list press 'q' or 'Q' 
and the ENTER key to do so.
  TestLength    (decimal value, 1-4294967295)   [100    ]
  FrameSize     (decimal value, 36-2148)        [256    ]
  DataPattern   (32-bit hex value or 'Default') [Default]
  StopOnError   (True/False)                    [False  ]
  Do you want to start the test? (y/n) [n]
4.
After all parameter values are defined, press the Y key to start the test. After 
the command executes, a message on the screen will appear detailing the 