GarrettCom 6K32 ユーザーズマニュアル

ページ / 65
Magnum 6K32 Managed Switch            Installation and User Guide (02/05) 
 
22 
www  GarrettCom  com
.
.
 
3.2.3 Connecting 
Single-Mode Fiber Optic 
When using single-mode fiber cable, be sure to use single-mode fiber port 
connectors.  Single-mode fiber cable has a smaller diameter than multi-mode fiber cable 
(9/125 microns for single-mode, 50/125 or 62.5/125 microns for multi-mode where xx/xx 
are the diameters of the core and the core plus the cladding respectively). Single-mode 
fiber allows full bandwidth at longer distances, and may be used to connect 10 Mb nodes 
up to 10 Km apart, or 18Km with the 6K-SSC. 
The same procedures as for multi-mode fiber applies to single-mode fiber 
connectors.  Follow the steps listed in Section 3.2.2 above. 
 
3.2.4 
Connecting Twisted Pair (RJ-45,CAT3, CAT5, Unshielded or Shielded) 
The RJ-45 ports of the Magnum 6K32 can be connected to the following two 
media types: 100BASE-TX and 10BASE-T.  CAT 5 cables should be used when making 
100BASE-TX connections. When the ports are used as 10BASE-T ports, CAT 3 may be 
used.  In either case, the maximum distance for unshielded twisted pair cabling is 100 
meters (328 ft). 
Media 
               
IEEE Standard          Connector  
Twisted Pair (CAT 3, 4, 5)                  10BASE-T                  RJ-45 
          
Twisted Pair (CAT 5)  
 100BASE-TX                RJ-45            
 
NOTE :   It is recommended that high quality CAT. 5 cables (which work for both 10 Mb 
and 100Mb) be used whenever possible in order to provide flexibility in a 
mixed-speed network, since dual-speed ports are auto-sensing for either 10 and 
100Mb/s.
  
  The following procedure describes how to connect a 10BASE-T or 100BASE-
TX twisted pair segment to the RJ-45 port. The procedure is the same for both 
unshielded and shielded twisted pair cables. 
1.    Using standard twisted pair media, insert either end of the cable with an RJ-45 
plug into the RJ-45 connector of the port. Note that, even though the connector is 
shielded, either unshielded or shielded cables and wiring may be used.  
2.   Connect the other end of the cable to the corresponding device 
3.   Use the LINK LED to ensure proper connectivity by noting that the LED 
will be illuminated when the unit is powered and proper connection is 
established
 
 
3.2.5 
Connecting Twisted Pair (CAT5E or better, Unshielded or Shielded) 
The RJ-45 Gigabit ports of the Magnum 6K32 can be connected to the media 
types, 1000BASE-T or CAT 5E or better 100-ohm UTP or shielded twisted pair (STP) 
balanced cable.  The CAT 5E or better 100-ohm UTP or shielded twisted pair (STP) 
balanced cable is recommended to use when making 1000BASE-TX connections.   In 
either case, the maximum distance for unshielded twisted pair cabling is 100 meters (328 
ft).  See Section 4.3 for manual Up-Link switch on port 1 of copper port modules.