HP (Hewlett-Packard) A3100-16-PoE v2 EI ユーザーズマニュアル

ページ / 157
 
To do… 
Use the command… 
Remarks 
Set the maximum number of 
configuration files that can be 
saved 
archive configuration max 
file-number 
Optional 
The default number is 5. 
 
 
NOTE: 
• 
If the undo archive configuration location command is executed, the running configuration cannot be
saved either manually or automatically, and the configuration is restored to the default by executing the
archive configuration interval and archive configuration max commands. The saved configuration 
files are cleared. 
• 
The value of the 
file-number
 argument is determined by memory space. Set a comparatively small value
for the 
file-number
 argument if the available memory space is small. 
 
Enabling automatic saving of the running configuration 
You can configure the system to save the running configuration at a specified interval, and use the 
display archive configuration command to view the filenames and save time of the saved configuration 
files. This enables you to easily roll back the current configuration to a previous configuration state. 
Configure an automatic save interval based on the storage media’s performance and the frequency of 
configuration modification using the following guidelines: 
 
If the configuration of the switch does not change frequently, manually save the running 
configuration as needed 
 
Save the running configuration manually, or configure automatic saving with an interval longer 
than 1,440 minutes (24 hours).  
Follow these steps to enable automatic saving of the running configuration: 
To do… 
Use the command… 
Remarks 
Enter system view 
system-view 
— 
Enable the automatic saving of 
the running configuration, and set 
the interval 
archive configuration interval 
minutes 
Optional 
Disabled by default 
 
 
NOTE: 
The path and filename prefix for saving configuration files must be specified before you configure the 
automatic saving period. 
 
Manually saving the running configuration 
Automatic saving of the running configuration occupies system resources, and frequent saving can 
greatly affect system performance. If the system configuration does not change frequently, disable 
automatic saving of the running configuration and save it manually. 
In addition, automatic saving of the running configuration is performed periodically, while manual 
saving can be used to immediately save the running configuration. Before performing a complicated 
configuration, manually save the running configuration so that the switch can revert to the previous state 
if the configuration fails. 
Follow the step below to manually save the running configuration: 