Brocade Communications Systems 6910 ユーザーズマニュアル

ページ / 80
Brocade 6910 Ethernet Access Switch MIB Reference
31
53-1002582-01
Chapter
6
User Access
Agent user access group
This chapter presents the objects used to control user access to devices.
The objects in this section apply to user accounts
General security objects
The following objects are used to manage general security functions.
Name, Identifier, and Syntax
Access
Description
snAgWebMgmtServerTcpPort
brcdIp.1.1.2.1.64
Syntax: Integer
Read-write
This object allows you to specify which TCP port will be used for 
the Web management interface. 
Enter a number from 1 – 65535.
Name, Identifier, and Syntax
Access
Description
snAgGblTelnetTimeout
brcdIp.1.1.2.1.37
Syntax: Integer
Read-write
Shows how many minutes a Telnet session can remain idle 
before it times out. The value of this object can be up to 1093 
minutes.
snAgGblEnableWebMgmt
brcdIp.1.1.2.1.38
Syntax: Integer
Read-write
Enables or disables access to the device from the Web 
management interface:
disable(0)
enable(1)
Default: enable(1)
snAgGblEnableTelnetServer
brcdIp.1.1.2.1.45
Syntax: Integer
Read-write
Enables or disables the Telnet server in a device:
Disable(0)
Enable(1)
Default: enable(1)
snAgGblTelnetLoginTimeout
brcdIp.1.1.2.1.60
Syntax: Integer
Read-write
Indicates how many minutes you have to log in before Telnet is
disconnected.
Valid values: 1 – 5 minutes.
Default: 5 minutes