McDATA 3032 ユーザーズマニュアル
4
4-8
Repair Information
.
Figure 4-3
Sphereon
3032 and 3232
Event Log
The log contains the following columns:
•
Date/Time -
the date and time the switch event occurred.
•
Event -
the three-digit event code associated with the event. Refer
to
"for an explanation of event
codes.
•
Description -
a brief description of the event.
•
Severity -
the severity of the event (Informational, Minor, Major, or
Severe).
•
FRU-Position -
an acronym representing the FRU or non-FRU
elements, followed by a number representing the FRU or chassis
position. The acronyms are:
position. The acronyms are:
— SFP - Small form factor pluggable (SFP) optical transceiver.
Chassis slots for SFPs inserted in a port are 0 through
31
.
SFPs
are FRUs.
— PWR - power supply. Chassis slots for redundant power
supplies are 0 and 1. Power supplies are FRUs.
— FAN - cooling fan. Chassis slots for redundant fans are 0
through
3
. Fans are FRUs.
— CTP - control processor (CTP) card. The chassis slot is 0. The
CTP card is not a FRU.
— THM - thermal sensor. The chassis slot is 0. The thermal
sensor is not a FRU.
•
Event Data -
up to 32 bytes of supplementary event data (if
"for an explanation of the supplementary
event data.