Lucent Technologies 1100 ユーザーズマニュアル
Troubleshooting
4-6
Issue 1 June 1998
Table 4-3 shows the LED flashes that may occur on the Switch
Module after the power-up LED sequence.
Module after the power-up LED sequence.
Table 4-3.
Module LED Blink Sequence
LED
Sequence
Sequence
Meaning
G
Module is online to a Remote Module; no
abnormalities have been detected.
abnormalities have been detected.
GG
Module is in COD (Call on Demand) waiting
mode; no abnormalities have been detected.
mode; no abnormalities have been detected.
GGG
Module is idle and waiting for connect sequence;
no abnormalities have been detected.
no abnormalities have been detected.
R
DSP is off-line. Try to power cycle the module. If
continues, contact the Helpline.
continues, contact the Helpline.
RR
Module is waiting for connection to DEFINITY
DCP port. (PHONE/SWITCH port on the
Extender is not connected) Check the
connection and that the distance between the
DEFINITY ECS port and the Switch Module is
within 500 ft.
DCP port. (PHONE/SWITCH port on the
Extender is not connected) Check the
connection and that the distance between the
DEFINITY ECS port and the Switch Module is
within 500 ft.
RRR
Modem error. Try to power cycle the module. If it
continues, contact the Helpline.
continues, contact the Helpline.
Y
Modem is trying to connect, or modem is
disconnecting. No abnormalities have been
detected.
disconnecting. No abnormalities have been
detected.