8-Port 10/100 Ethernet Switch with Webview
Port 
 
Displays  the  RMON  statistics  for  the  selected 
port.
LAG 
 
Displays  the  RMON  statistics  for  the  selected 
LAG.
Counter Name 
Displays the selected MIB variable.
Sample  Type 
Defines  the  sampling  method  for  the 
selected  variable  and  comparing  the  value  against  the 
thresholds. The possible field values are:
Absolute 
 
Compares  the  values  directly  with  the 
thresholds at the end of the sampling interval.
Delta 
 
Subtracts  the  last  sampled  value  from  the 
current value. The difference in the values is compared 
to the threshold.
Rising Threshold 
Displays the rising counter value that 
triggers  the  rising  threshold  alarm. The  rising  threshold 
is  presented  on  top  of  the  graph  bars.  Each  monitored 
variable is designated a color.
Rising Event 
Displays the mechanism in which the alarms 
are reported. The possible field values are: 
LOG 
 
Indicates  there  is  not  a  saving  mechanism  for 
either the device or in the management system. If the 
device is not reset, the entry remains in the Log Table. 
TRAP 
 
Indicates that an SNMP trap is generated, and 
sent  via  the  Trap  mechanism.  The  Trap  can  also  be 
saved using the Trap mechanism. 
Both 
 
Indicates that both the Log and Trap mechanism 
are used to report alarms.
Falling Threshold 
Displays the falling counter value that 
triggers the falling threshold alarm. The falling threshold 
is  graphically  presented  on  top  of  the  graph  bars.  Each 
monitored variable is designated a color.
Falling  Event 
Displays  the  mechanism  in  which  the 
alarms are reported. The possible field values are: 
LOG 
 
Indicates  there  is  not  a  saving  mechanism  for 
either the device or in the management system. If the 
device is not reset, the entry remains in the Log Table. 
TRAP 
 
Indicates  that  a  SNMP  trap  is  generated,  and 
sent  via  the  Trap  mechanism.  The  Trap  can  also  be 
saved using the Trap mechanism. 
Both 
 
Indicates that both the Log and Trap mechanism 
are used to report alarms.
Startup  Alarm 
Displays  the  trigger  that  activates  the 
alarm  generation.  Rising  is  defined  by  crossing  the 
threshold  from  a  low-value  threshold  to  a  higher-value 
threshold.
Interval 
Defines the alarm interval time in seconds.
Owner 
Displays  the  device  or  user  that  defined  the 
alarm.
The  Add  to  List  button  adds  the  RMON  Alarms  Table 
entry.
The  Alarm  Table  area  contains  the  following  additional 
field:
Counter Value 
Displays the current counter value for the 
particular alarm.
Statistics > RMON Events
An RMON Event determines the action to take when an 
alarm is triggered. The response to an alarm can include 
logging the alarm or sending an SNMP trap message. If 
the response corresponding to an alarm has not yet been 
defined, use the RMON Event screen to configure the Event 
Setting table.
Statistics > RMON Events
Add Event
Event Entry 
Displays the event.
Community 
Displays the community to which the event 
belongs.
Description 
Displays the user-defined event description.
Type 
Describes the event type. Possible values are:
None 
 
Indicates that no event occurred.
Log 
 
Indicates that the event is a log entry.
Trap 
 
Indicates that the event is a trap.
Log and Trap 
 
Indicates that the event is both a log 
entry and a trap.
Owner 
Displays  the  device  or  user  that  defined  the 