Linksys SGE2000 ユーザーズマニュアル

ページ / 50
9
Chapter 3: Connecting the Switch
Placement Options
Linksys One Ready Communications Solution
Chapter
3
units to be logically stacked together. It is recommended that multiple Ethernet switches 
be mounted in a rack when installed in this manner. Ethernet switches can be physically 
placed at different locations; they do not have to be stacked at the same location.
Placement Options
Before connecting cables to the Ethernet switch, first you will physically install the Ethernet 
switch. Either set the Ethernet switch on its four rubber feet for desktop placement, mount it in 
a standard-sized, 19-inch wide for rack-mount placement, or mount it on a wall with the 
wall-mount brackets provided.
Desktop Placement
1. Attach the rubber feet to the recessed areas on the bottom of the Ethernet switch.
2. Place the Ethernet switch on a desktop near an AC power source.
Rack-Mount Placement
To mount the Ethernet switch in any standard-sized, 19-inch wide, (each Ethernet switch 
requires 1RU of space in the rack), follow these instructions:
1. Remove the four front screws on one side of the Ethernet switch. Retain the screws for re-
installation.
2. Place one of the supplied spacers on the side of the Ethernet switch so the four holes 
align to the screw holes.
NOTE: 
The four supplied mounting 
brackets can be used for either wall 
mount or rack mount installations.
CAUTION: 
Keep enough ventilation 
space for the Ethernet switch so it does 
not exceed the environmental 
restrictions mentioned in the 
specifications.