SMART CAT5 SWITCH 16 IP
.
 
39
 
Modem Server IP address – This address is used only when connecting to Smart 
16 IP via a modem. When you dial into the Smart 16 IP the client computer will 
receive a Modem Client IP address from the Smart 16 IP. Open the Web browser 
and type Modem server IP address to login to the Smart 16 IP. 
The Client IP (see paragraph below) must be in the same class C subnet as the 
server IP. This subnet should not conflict with the Ethernet subnet on the client 
side and with the Ethernet subnet on Smart 16 IP Network side. 
Modem Client IP address - This address is assigned to your console computer 
during the PPP handshake. Since it is a point-to-point IP connection virtually 
every IP address is possible but ensure, it is not interfering with the IP settings of 
Smart 16 IP and your console computer. The default value will work in most 
cases.  
IPMI over Serial - Check to use this serial port for IPMI 1.5 over serial. See 
page 47 for more information.  
Passthrough access to serial port via Telnet - Connect an arbitrary device to the 
serial port and access it (assuming it provides terminal support) via telnet. Select 
the appropriate options for the serial port and use the Telnet Console (see page 
42) or a standard telnet client to connect to Smart 16 IP. For more information, 
see page 19.  
External Power Option – When the External Power Option is the Sentry 
Power Tower or Baytec RPC series connected to Serial port 1, configure it by 
clicking change external power switch option. The External Power Option for 
Serial port 1 window appears. 
Fill in the Username and password as defined by the Sentry Power Tower. 
 
Figure 27 External Power Option for Serial port 1