B-6   Management Workstation Application
Configuring Server BIOS Setup
To use MWA, you must configure the server's BIOS with three specific settings
enabled. These settings take place in Advanced Menu and the Hardware Menu
of the BIOS Setup. (Refer to Chapter 3, “Configuring Your System,” for BIOS
Setup information.) The following table shows the settings that must be enabled
to use MWA.
Menu Parameter Name
Required Setting for
MWA
ADVANCED MENU
Advanced
Press Enter for menu.
ROMPilot Support
Enabled
Peripheral Configuration
Press Enter for menu.
LAN controller
Enabled
SYSTEM HARDWARE MENU
Wake On LAN
Enabled
Installing MWA on the Management PC
To Install MWA on the management PC perform the following procedure.
1.  Start Windows95 / Windows 98 / or Windows NT on the management PC.
2.  Insert the E
XPRESS
B
UILDER 
CD into the PC CD-ROM drive.
3.  Using Explorer, execute "setup.exe" in MWA folder of the CD-ROM. MWA
installer will start.
4.  Follow MWA installer instructions.
Note:
 MWA will be registered in the Startup folder after
installation, and started automatically when an OS start (Log
in) is initiated.
Registering SG Information on MWA
In order for MWA to connect with a server, the server system generation
information (SG) must be set and registered on MWA.
In this procedure SG information is registered on MWA from the server System
Generation diskette (SG) created in the section Creating a Server System
Generation diskette (SG).
1.  Run MWA on the management PC and select the New SG command from
File menu.  The Create a New Server dialog box displays.