HP (Hewlett-Packard) BL685C G6 ユーザーズマニュアル
Component identification 62
•
Processor 4 DIMM slots
System maintenance switch
Position Function
Default
1*
iLO 2 security override
Off
2 Configuration
lock
Off
3 Reserved
Off
4 Reserved
Off
5* Password
disabled
Off
6* Reset
configuration
Off
7 Reserved
Off
8 Reserved
Off
*To access redundant ROM, set S1, S5, and S6 to ON.
System maintenance switch procedures
When you perform troubleshooting steps, this guide may instruct you to perform the following procedures:
•
Clear the system configuration ("
•
Access the redundant ROM ("
To complete these procedures, you must change physical settings on the system maintenance switch.
Clearing the system configuration
RBSU can be used to restore the factory default configuration. For more information, see "HP ROM-Based
Setup Utility." If the system is unable to boot into RBSU, use the following steps to clear the system
Setup Utility." If the system is unable to boot into RBSU, use the following steps to clear the system
configuration:
1.
Power down the server blade (on page
2.
Remove the server blade (on page