HP (Hewlett-Packard) L700 (CTL700) ユーザーズマニュアル

ページ / 154
D- 1
D
Con
Library for the NonStop NS-Series 
Server
This section covers:
Fibre Channel ServerNet Adapter Connection
You can attach the CTL700 tape library (control path and data paths) to a 
NonStop
 N
S-series server using a Fibre Channel ServerNet adapter (FCSA).
The control path and SCSI tape drives (CT9840-1, N1521A, and 5259
will need to be 
connected to a M8201 Fibre Channel converter before connecting to a FCSA on a 
NonStop NS-Series server.
For more information about the router, refer to the M8201 Fibre Channel 
to SCSI Router Installation and User’s Guide.
All Fibre Channel tape drives (CT9840FC-1, CT9841FC-1, and M8503) connect 
directly to the FCSA on the NonStop NS-series server by using a fiber optic cable.
Configuration
Configuring SCSI Tape Drives
1. In SCF, issue this command:
SCF> ADD TAPE $tape, SENDTO STORAGE, LOCATION (group, module, 
slot), SAC sac-id, PORTNAME 64-bit-portname, LUN lun-id
Example: 
SCF> ADD TAPE $TAPE1, SENDTO STORAGE, LOCATION (1,1,51), SAC 
1, PORTNAME 100000E00C00F000,LUN 1
Note.
The control path is used to control the robot and the data path is used to control the 
tape drives.
Note.
LUN in SCF should be 1 for the tape drive that is on bus 0. Lun in SCF should be 3 for 
the tape drive that is on bus 1.
Note.
PORTNAME in SCF corresponds to the WWP name of the router. This name is located 
on the back of the device. See