HP (Hewlett-Packard) 9000 V2500 SCA ユーザーズマニュアル

ページ / 206
162
Chapter 7
 
Recovering from failures
Abnormal system shutdowns
Following the dump, the system attempts to reboot.
The reboot
When dumping of physical memory pages is complete, the system 
attempts to reboot (if the Autoboot is set). For information on the 
Autoboot flag, see “Enabling Autoboot” on page 67. 
savecrash processing
During the boot process, a process called 
savecrash
 can be used that 
copies (and optionally compresses) the memory image stored on the 
dump devices to the HP-UX file system area.
Dual-mode devices (dump / swap)
By default, 
savecrash
 performs its copy during the boot process. 
Disable this operation by editing the file: 
/etc/rc.config.d/
savecrash
 and setting the 
SAVECRASH
 environment variable to a value 
of zero. This is generally safe to do if the dump devices are not also being 
used as paging devices. 
WARNING
If using devices for both paging and dumping, do not disable 
savecrash boot processing. Loss of the dumped memory image to 
subsequent system paging activity can occur.
What to do after the system has rebooted?
After the system reboots, make sure that the physical memory image 
dumped to the dump devices is copied to the HP-UX file system area 
then either package and send it in for analysis or analyze it using a 
debugger.
NOTE
With HP-UX 11.0, it is possible to analyze a crash dump directly from 
dump devices. If, however, it needs to be saved to a tape or sent to 
someone, first copy the memory image to the HP-UX file system area.
Unless specifically disabled during reboot, the 
savecrash
 utility copies 
the memory image during the reboot process. The default HP-UX 
directory for the memory image in is 
/var/adm/crash
. Specify a 
different location by editing the file 
/etc/rc.config.d/savecrash
 
and setting the environment variable called 
SAVECRASH_DIR
 to the 
name of the directory the dumps are to be located.