Chapter 2
System Specifications
Electrical Specifications
64
NOTE
A qualified electrician must wire the PDCA receptacle to site power using copper wire and in 
compliance with all local codes.
All branch circuits used within a complex must be connected together to form a common ground. All power 
sources such as transformers, UPSs, and other sources, must be connected together to form a common ground.
When only one PDCA is installed in a system cabinet, it must be installed as PDCA 0. Refer to Figure 2-1 for 
the location of PDCA 0.
NOTE
When wiring a PDCA, phase rotation is unimportant. When using two PDCAs, however, the 
rotation must be consistent for both.
7
3-phase 
Voltage range 200 
to 240 V ac, 
phase-to-neutral, 
50 Hz / 60 Hz
5-wire
24 A maximum 
per phase
Connector and plug 
provided with a 2.5 meter 
(8.2 feet) power cable. 
Electrician must hard wire 
receptacle to 32 A site 
power.
a. A dedicated branch circuit is required for each PDCA installed.
Table 2-7
Option 6 and 7 Specifics
PDCA 
Part Number
Attached Power Cord
Attached Plug
Receptacle 
Required
A5201-69023
(Option 6)
OLFLEX 190 (PN 600804) is a 2.5 meter (8.2 feet) 
multi conductor, 600 V, 90° C, UL and CSA 
approved, oil resistant flexible cable (8 AWG 60 A 
capacity).
Mennekes 
ME 460P9
(60 A capacity)
Mennekes 
ME 460R9
(60 A capacity)
A5201-69024
(Option 7)
H07RN-F (OLFLEX PN 1600130) is a 2.5 meter 
(8.2 feet) heavy-duty neoprene-jacketed 
harmonized European flexible cable (4 mm
2
 32 A 
capacity).
Mennekes 
ME 532P6-14 
(32 A capacity)
Mennekes 
ME 532R6-1500
(32 A capacity)
Table 2-6
Available Power Options (Continued)
Option
Source 
Type
Source Voltage 
(Nominal)
PDCA
Required
Input Current 
Per Phase 200 
to 240 V ac 
a
Power Receptacle 
Required