MSA2000 Chassis
POWER REQUIREMENTS
Input Power
Requirements
110 VAC 3.6A/394W; 220VAC 1.9/385W
Max Input Power
100-240 VAC, 50/60 Hz., 4.5-1.9A; 48-60 VDC 10.4A/8.3A
Heat Dissipation
1622 BTU/hr
TEMPERATURE AND HUMIDITY RANGES
Operating Temperature
41°F to 104°F (5oC to 40°C)
Shipping Temperature
-40°F to 158°F (-40°C to 70°C)
Operating Humidity
10% to 90% RH @ 104°F (40°C) non-condensing
Non-Operating Humidity Up to 93% RH @ 104°F (40°C)
DECLARED ACOUSTIC NOISE LEVELS
Sound Power
< 6.5 Bels
Sound Pressure
< 57 dBA
SHOCK AND VIBRATION
Shock, Operational
5G's for 11 milliseconds, half sine
Shock, Non-Operational 15G 11ms half sine
Vibration, Operational
5-500Hz, 0.21Grms flat spectrum0.000089g2/HZ Random Vibration
Vibration, Non-
Operational
5-500-5Hz, 0.5 G peak to peak, sinusoidal
PHYSICAL
Height
3.436 in/ 8.727 cm
Depth (excluding cables)
(back of ear to back of
controller handle)
MSA2024: 20.28 in / 51.510 cm
MSA2012: 21.8 in. / 55.372 cm
Width (body only)
17.55 in / 44.58 cm (w/ ears 19 in / 48.26 cm)
Chassis Weight
(no controllers)
MSA2012 chassis: 44 lbs. MSA2024 chassis: 43 lbs
 
 
 
MSA2000sa G2
Controller
Host Interface
4 x4 lane SAS ports - 3Gb/s per lane
Protocol Support
SAS
RAID Support
0, 1, 3, 5, 6, 10, 50
Cache Memory
1GB Read/Write
Cache Backup
ECC protection with back up to flash memory ( indefinite backup)
Upgradeable Firmware yes
Disk Drive and
Enclosure Protocol
Support
3Gb SAS - Serial Attached SCSI / 3 Gb SATA II
Expansion Port
One 4X SAS connector (SFF8470) Expand up to 3 more drive
enclosures
 
 
 
QuickSpecs
HP StorageWorks 2000sa G2 Modular Smart Array
Technical Specifications
DA - 13331   Worldwide QuickSpecs — Version 2 — 7.31.2009
Page 23