Dimensions / Weight 
Ventilation clearance
At least 200 mm on the front and rear.
Ambient conditions
Condensation during operation must be avoided!
Noise level
Rack (W x D x H)
482.6 mm (Bezel) / 444.8 mm (Body) x 770.0 mm x 
176.0 mm
Mounting depth rack
728 mm
Height unit rack
4 U
19" rackmount
Yes
Mounting cable depth 
rack
100 mm (1000 mm rack recommended)
Weight
min. 32 kg; max. 46 kg (actual weight may vary 
depending on configuration)
Rack integration kit
rack integration kit as option
I
Rack integration kit is standard for the 
japanese market.
Environment class 3K2
Environment class 2K2
EN 60721 / IEC 721 Part 3-3
EN 60721 / IEC 721 Part 3-2
Temperature:
Operation (3K2)
10 °C .... 35 °C
Transport (2K2)
-25 °C .... 60 °C
Humidity
10% ... 85%   (non condensing)
Sound power level L
WAd
 (ISO 9296)
< 6.2 B (standby)
< 6.6 B (operation)
Sound pressure level at bystander position L
pAm
 
(ISO 9296) (at < 23 °C)
< 46 dB(A) (standby)
< 51 dB(A) (operation)