HP (Hewlett-Packard) 686713-S01 ユーザーズマニュアル

ページ / 127
 
Setup  34 
Rack warnings 
   
 
WARNING:
  To reduce the risk of personal injury or damage to the equipment, be sure that: 
 
The leveling jacks are extended to the floor. 
 
The full weight of the rack rests on the leveling jacks. 
 
The stabilizing feet are attached to the rack if it is a single-rack installation.  
 
The racks are coupled together in multiple-rack installations.  
 
Only one component is extended at a time. A rack may become unstable if more than one 
component is extended for any reason.   
   
 
   
 
WARNING:
  To reduce the risk of personal injury or equipment damage when unloading a rack: 
 
At least two people are needed to safely unload the rack from the pallet. An empty 42U rack 
can weigh as much as 115 kg (253 lb), can stand more than 2.1 m (7 ft) tall, and might 
become unstable when being moved on its casters. 
 
Never stand in front of the rack when it is rolling down the ramp from the pallet. Always handle 
the rack from both sides. 
   
 
   
 
WARNING:
  When installing a server in a telco rack, be sure that the rack frame is adequately 
secured to the top and bottom of the building structure. 
   
 
Server warnings and cautions 
   
 
WARNING:
  This server is very heavy. To reduce the risk of personal injury or damage to the 
equipment: 
 
Observe local occupational health and safety requirements and guidelines for manual 
material handling. 
 
Get help to lift and stabilize the product during installation or removal, especially when the 
product is not fastened to the rails. When the server weighs more than 22.5 kg (50 lb), at least 
two people must lift the server into the rack together. A third person may be required to help 
align the server if the server is installed higher than chest level. 
 
Use caution when installing the server in or removing the server from the rack; it is unstable 
when not fastened to the rails. 
   
 
   
 
WARNING:
  To reduce the risk of personal injury from hot surfaces, allow the drives and the 
internal system components to cool before touching them. 
   
   
 
WARNING:
  To reduce the risk of personal injury, electric shock, or damage to the equipment, 
remove the power cord to remove power from the server. The front panel Power On/Standby 
button does not completely shut off system power. Portions of the power supply and some internal 
circuitry remain active until AC power is removed. 
   
   
 
CAUTION:
  Protect the server from power fluctuations and temporary interruptions with a 
regulating uninterruptible power supply (UPS). This device protects the hardware from damage 
caused by power surges and voltage spikes and keeps the system in operation during a power 
failure.