HP (Hewlett-Packard) 642106-001 ユーザーズマニュアル

ページ / 134
 
Component identification  21 
FBWC module LEDs (P222, P420, P421) 
The FBWC module has three single-color LEDs (one amber and two green). The LEDs are duplicated on the 
reverse side of the cache module to facilitate status viewing. 
 
     
1 - Amber 
2 - Green 
3 - Green 
Interpretation 
Off 
Off 
Off 
The cache module is not powered. 
Off 
Flashing 0.5 Hz  Flashing 0.5 Hz  The cache microcontroller is executing from within its 
boot loader and receiving new flash code from the host 
controller. 
Off 
Flashing 1 Hz 
Flashing 1 Hz 
The cache module is powering up, and the capacitor 
pack is charging. 
Off 
Off 
Flashing 1 Hz 
The cache module is idle, and the capacitor pack is 
charging. 
Off 
Off 
On 
The cache module is idle, and the capacitor pack is 
charged. 
Off 
On 
On 
The cache module is idle, the capacitor pack is charged, 
and the cache contains data that has not yet been 
written to the drives. 
Off 
Flashing 1 Hz 
Off 
A backup is in progress. 
Off 
On 
Off 
The current backup is complete with no errors. 
Flashing 1 Hz 
Flashing 1 Hz 
Off 
The current backup failed, and data has been lost. 
Flashing 1 Hz 
Flashing 1 Hz 
On 
A power error occurred during the previous or current 
boot. Data may be corrupt. 
Flashing 1 Hz 
On 
Off 
An overtemperature condition exists. 
Flashing 2 Hz 
Flashing 2 Hz 
Off 
The capacitor pack is not attached. 
Flashing 2 Hz 
Flashing 2 Hz 
On 
The capacitor has been charging for 10 minutes, but 
has not reached sufficient charge to perform a full 
backup. 
On 
On 
Off 
The current backup is complete, but power fluctuations 
occurred during the backup. 
On 
On 
On 
The cache module microcontroller has failed. 
 
 
Hot-plug fans