CAUTION!
Because of chassis airflow disruption, the power supply unit slot should 
not be vacant and/or uncovered for more than five minutes when the 
system power is ON. Exceeding the five-minute limit may damage 
components.
All unoccupied PSU slots in the blade server system are fitted with PSU dummy 
modules (
) to ensure that the electromagnetic emission properties of 
the system are observed and that the system components are properly cooled.
Each PSU dummy module includes three fans respectively.
There is one LED indicator (1 on 
) on the front of the PSU dummy 
module for monitoring the status of built-in fans.
Figure 94: PSU dummy module
If you want to install an additional power supply unit, you must first remove the 
PSU dummy module from the corresponding slot.
Ê
Remove the PSU dummy module from the corresponding slot.
Removal/installation is the same as for the power supply unit (see 
1