Hardware options installation  51 
Enabling the dedicated iLO management port 
The onboard NIC 1/shared iLO connector is set as the default system iLO port. 
To enable the installed dedicated iLO module: 
1. 
During the server startup sequence after module installation, to access iLO RBSU, press the F8 key. 
2. 
Select the Network menu. 
3. 
Click the Network Interface Adapter field. 
4. 
To change the setting to ON, press the spacebar. 
5. 
To save the new settings, press the F10 key. 
6. 
Select the File menu, and then to close iLO RBSU, click Exit. 
7. 
To confirm exiting iLO RBSU, click OK. The server automatically reboots. 
  
 
IMPORTANT:
 If the iLO RBSU settings are reset to the default values, access to the machine will be 
lost. Access the physical machine, and then set the Network Interface Adapter field to ON. 
  
 
HP Trusted Platform Module option 
Use these instructions to install and enable a TPM on a supported server. This procedure includes three 
sections: 
1. 
Installing the Trusted Platform Module board. 
2. 
Retaining the recovery key/password (on page 
). 
3. 
Enabling the Trusted Platform Module (on page 
). 
Enabling the TPM requires accessing RBSU ("
" on page 
). For more 
information about RBSU, see the HP website (
). 
TPM installation requires the use of drive encryption technology, such as the Microsoft Windows BitLocker 
Drive Encryption feature. For more information on BitLocker, see the Microsoft website 
). 
  
 
CAUTION: 
 Always observe the guidelines in this document. Failure to follow these guidelines 
can cause hardware damage or halt data access. 
  
When installing or replacing a TPM, observe the following guidelines: 
 
Do not remove an installed TPM. Once installed, the TPM becomes a permanent part of the system 
board. 
 
When installing or replacing hardware, HP service providers cannot enable the TPM or the encryption 
technology. For security reasons, only the customer can enable these features. 
 
When returning a system board for service replacement, do not remove the TPM from the system board. 
When requested, HP Service provides a TPM with the spare system board. 
 
Any attempt to remove an installed TPM from the system board breaks or disfigures the TPM security 
rivet. Upon locating a broken or disfigured rivet on an installed TPM, administrators should consider the 
system compromised and take appropriate measures to ensure the integrity of the system data. 
 
When using BitLocker, always retain the recovery key/password. The recovery key/password is 
required to enter Recovery Mode after BitLocker detects a possible compromise of system integrity.