Fujitsu TX200 S6 ユーザーズマニュアル
106
Operating Manual
TX200
S6
CSS components
Ê
Disconnect the fan cable from the connector FAN2 (if there is a second fan
cable, disconnect this from FAN4) on the system board (see the technical
manual for the system board D2799).
cable, disconnect this from FAN4) on the system board (see the technical
manual for the system board D2799).
Ê
Press the two green locks of the air duct together (1).
Ê
Press the green lock of the air duct in the direction of the arrow (2).
Ê
Lift the air duct with the integrated system fan 2 (and 4) up and out (3).
8.2.1.3
Removing system fan 1 (and 3)
Ê
Remove system fan 2 (and 4) (see
).
Figure 30: System fan 1 and system fan 1&3
The standard system fan 1 is shorter and has just one fan cable; the redundant
system fan 1&3 is taller (as 2 fans are integrated internally) and has two fan
cables.
system fan 1&3 is taller (as 2 fans are integrated internally) and has two fan
cables.
The procedure for installing and removing both system fans is identical except
for connecting the fan cables.
for connecting the fan cables.