CHAPTER 8 Chapter System Startup/Shutdown and Power Control 
8.3 Scheduled operations 
164 
 
C122-E175-01EN 
 
Time till the instruction reaches the operating system from the MMB 
Time until the operating system shutdown is started and time until the start of the operating system 
shutdown is notified to the MMB 
Even if the [Power on Delay] is set to 0 seconds, it may take 30 ~ 70 seconds from the time of turning on 
the power and starting, up to reset.  
For the scheduled setting, see ‘1.3.2 [Schedule] menu’ in “PRIMEQUEST 2000 series Tool Reference” 
(C122-E177). 
8.3.2  Power off a Partition by scheduled operation 
When a scheduled operation is set for a partition set, power is turned off at the set time.  
A daily, weekly, monthly, specific date or a combination of these options can be set a schedule.                                                                                                                                                                                         
For the details on schedule settings, see ‘1.3.2 [Schedule] menu’ in “PRIMEQUEST 2000 series Tool 
Reference” (C122-E177). 
8.3.3  Relation of scheduled operation and power restoration function 
In the PRIMEQUEST 2000 series, scheduled operation and power restoration function are linked when power 
restoration mode is set to “Schedule Sync”. 
 TABLE 8.5 Relationship between scheduled operation and partition power restoration mode 
No. 
When there is power 
failure 
When the power is 
restored 
Always OFF 
(*1) 
Always ON 
(*1) 
Restore (*1) 
Schedule 
Sync 
(*1) 
Outside the operation 
time 
Within the operation 
time 
OFF 
ON 
OFF 
ON 
Within the operation 
time 
Within the operation 
time 
OFF 
ON 
ON 
ON 
Outside the operation 
time 
Outside the operation 
time 
OFF 
ON 
OFF 
OFF 
Within the operation 
time 
Outside the operation 
time 
OFF 
ON 
ON 
OFF 
ON: Partition Power On, OFF: Partition Power Off 
Notes 
Operations indicated by (*1) in the table, assume normal shutdown when a power failure occurs. If there is an 
abnormal power off because the UPS had not been used, the partition will not automatically start (= OFF 
mode operation) in a restoration operation, irrespective of the operation settings. 
8.3.4  Scheduled operation support conditions 
The description of power on/off items, scheduled operation support conditions and menu items are listed in 
the table below. 
 TABLE 8.6 Power on/off 
Menu Item 
Scheduled 
operations 
Description 
All Partition Power On 
Not supported 
Powers on all partitions. 
All Partition Power Off 
Not supported 
Powers off all the partitions which are in powered 
on, following an operating system shutdown. 
Partition Power On 
Supported 
Powers on any partition. 
Partition Power Off 
Supported 
Powers off any partition following an operating 
system shutdown. 
Partition Force Power Off 
Not supported 
Forcibly powers off any partition without an 
operating system shutdown. This is used, to forcibly 
power off a partition, when the shutdown from the 
operating system is disabled. 
Power Cycle 
Not supported 
Powers off and then powers on any partition. The 
partition is forcibly powered off without an operating 
system shutdown.