HP (Hewlett-Packard) RP4410 ユーザーズマニュアル

ページ / 288
Chapter 5
Troubleshooting
Troubleshooting Using LED Indicators
163
QuickFind Diagnostic Panel LEDs
The QuickFind diagnostic panel is located under the top cover and is attached to the top of the power supply 
cage. The following definitions describe the status of the various LEDs and what is wrong with the indicated 
component.
NOTE
LED behavior is based on firmware. For changes in LED behavior, see your server firmware 
release notes.
Table 5-4 lists the QuickFind diagnostic panel LED definitions.
Table 5-4
QuickFind Diagnostic Panel LED Definitions
Item
LED 0
LED 1
LED 2
LED 3
Details
Processor
Socket 0
Socket 1
Socket 2
Socket 3
If the System LED (on front panel) is in the 
attention or fault state and the processor LED 
is on, then the processor or voltage regulator 
has failed—the processor module in the 
specified socket needs to be replaced.
If the thermal LED is in the warning or critical 
state and the processor LED is on, then the 
processor exceeded the warning or critical level
Subsystem
CPU 
board
Memory 
board
I/O 
board
n/a
A soldered voltage regulator has failed—the 
specified board must be replaced
I/O VRM
n/a
n/a
n/a
n/a
n/a
CPU VRM
n/a
n/a
n/a
n/a
n/a
Fan module
0
1
2
n/a
One or both fans in a fan module have 
failed—the module must be replaced.
Fan 2 is in front of the power supplies
Memory 
bank X (0-7)
DIMM 
xA
DIMM 
xB
DIMM 
xC
DIMM 
xD
The specified DIMM has failed—the DIMM 
must be replaced
If all the LEDs for a rank (0-7) are lit and the 
memory config error LED is lit, then the 
DIMMs in the specified rank are 
mismatched—replace mismatched DIMM
Check 
power 
supply
n/a
n/a
n/a
One of the power supplies or power supply fans 
have failed—replace the power supply. The 
faulty power supply LED (located on power 
supply) lights
Memory 
config error
n/a
n/a
n/a
The DIMMs in a rank are mismatched. All the 
DIMMs in the specified rank (0-7) lights
Processor 
config error
n/a
n/a
n/a
The processors are mismatched—replace 
mismatched processor
Missing 
component
n/a
n/a
n/a
A required component(s) is not installed in the 
system and thus preventing power up
System 
temp
n/a
n/a
n/a
The internal temperature of the server has 
exceeded the warning or critical level
Check event 
log
n/a
n/a
n/a
An event has occurred that requires attention