System Specifications
Physical and Environmental Specifications
Chapter 2
53
Physical and Environmental Specifications
Table 2-7 provides temperature and airflow information for minimum, typical, and maximum configurations 
for the HP 9000 rp4410 and rp4440servers. It also lists the server and rack weights and dimensions.
Table 2-7
Physical and Environmental Specifications
Condition
Weight
Overall Server
(W x D x H)
Typical 
Heat 
Release
Airflow, Nominal 
Airflow, at 
Maximum 
Ambient 
degrees C
a
a.
Derate maximum dry bulb temperature 1 degree per 300 meters above 900 meters.
180-264 
VAC
Server 
Alone
Rack
Pede-
stal
Rack
Pede-
stal
Min. 
Config.
410 Watts
175 
CFM
297 
m
3
/hr
250 
CFM
425 
m
3
/hr
88 lbs 
(40 kg)
 100 lbs 
(45.4 kg)
 
115 lbs 
(53 kg)
W: 19 in 
(48.2 cm)
D: 27.2 in 
(69.0 cm)
H: 6.8 in 
(17.3 cm) 
 W: 10.3 in 
(26.1 cm)
D: 27.4 in 
(69.5 cm)
H: 20.9 in 
(53.0 cm)
Max. 
Config.
1368 Watts
Typical 
Config.
1065 Watts
ASHRAE 
Class 1
Airflow cooling scheme (front to 
rear)
Min./ 
Config.
One CPU, one power supply, 1 GB DIMM, zero 
DVD, one HDD, zero PCI cards, one core I/O.
Max. 
Config.
Four CPUs, two power supplies, 128 GB DIMM, 
one DVD, two HDD, six PCI cards, two core I/O.
Typical 
Config.
Two CPUs, two power supplies, 16 GM DIMM, 
one DVD, two HDD, two PCI cards, one core I/O.