Installing the System
Installing Additional Components
Chapter 3
77
Step 1. If rack-mounted, slide the server out from the rack until it stops. (See “Extend the Server from the 
Step 2. Remove the top cover. (See “Removing the Top Cover” on page 73.)
Step 3. Grasp the fan unit locking handle, tilt it up, and pull out the fan from the chassis. (Figure 3-15)
IMPORTANT When one fan unit is removed from the server, the remaining fan units operate at full 
speed for two minutes. After two minutes a soft-shutdown of the server occurs.
Replacing a Hot-Swappable Fan Unit
To replace a hot-swappable I/O or power supply fan unit, follow these steps:
Step 1. Orient the fan unit by aligning the appropriate icon on the fan unit handle to the identical icon on 
the chassis wall.
Step 2. Push the fan unit firmly into the housing and close the handle until flush to the top of the chassis. 
The fan unit plugs into the power outlet on the system I/O board.
CAUTION
If the fan unit handle does not close completely, it is misaligned. Remove the fan unit 
and check that the alignment icons are oriented correctly.
Step 3. Check the QuickFind diagnostic panel LED indicating the replaced fan unit. See “QuickFind 
When the fan functions normally, the LED is off.
When the fan fails, the LED is lit.
Step 4. Replace the top cover. (See “Replacing the Top Cover” on page 74.)
I/O Baseboard Assembly
WARNING
Ensure that the system is powered off and all power sources have been disconnected 
from the server before removing or replacing the I/O baseboard assembly.
Voltages are present at various locations within the server whenever an ac power 
source is connected. This voltage is present even when the main power switch is in 
the off position.
Failure to observe this warning can result in personal injury or damage to 
equipment.
CAUTION
Failure to properly complete the steps in this procedure results in erratic system behavior or 
system failure. For assistance with this procedure, contact your local HP Authorized Service 
Provider.
Observe all ESD safety precautions before attempting this procedure. Failure to follow ESD 
safety precautions can result in damage to the server.