Fujitsu M3000 ユーザーズマニュアル

ページ / 8
4
8. The following steps will log in to the XSCF Shell and initialize the XSCF settings.
XSCF is a system control facility to set up and control the server. To initialize the XSCF settings, use the 
XSCF default user account.
a. Set the mode switch on the operator panel to the Service mode (
).
The key for the mode switch is supplied with the server.
FIGURE 2
Operator Panel
b. Turn the power source circuit breaker to "ON".
After the power is turned on, the server starts the XSCF initialization that can take up to 5 or more 
minutes. When the initialization completes, the XSCF STANDBY LED (
) on the operator panel 
lights.
c. After the XSCF initialization completes, enter default at the login prompt. 
d. Operate the mode switch within one minute according to the messages to change the mode switch.
A login authentication timeout will occur after one minute.
Location Number
Name
1
POWER LED
2
XSCF STANDBY LED
3
CHECK LED
4
Power button
5
Mode switch (Key switch)
login: default
Change the panel mode switch to Locked and press return...
Leave it in that position for at least 5 seconds. 
Change the panel mode switch to Service, and press return...
1
2
3
4
5