Nortel Networks NN43001-563 ユーザーズマニュアル

ページ / 492
Channel Identifier planning
189
Incorrect ISL channel numbering plans
This section describes numbering plan errors.
Gaps in ISL channel numbering sequence
shows
gaps in the ISL numbering plan sequence. A gap between channel numbers
causes the IP trunk card to be unable to associate the ISL channel number
with the B channel number. Therefore, only units 0 to 4 (loop shelf card 0
to loop shelf card 4) can be used.
Table 42
Channel numbering error, gap on one card
Unit number (from TN)
ISL Channel number
0
1
1
2
2
3
3
4
4
5
5
11
6
12
Decreasing channel numbering sequence
shows an example of a decreasing ISL channel numbering plan.
Using decreasing ISL channel identifiers causes the IP trunk card to be
unable to associate the ISL channel number with the B channel number. In
this example, only unit 0 (loop shelf card 0) can be used.
Table 43
Channel numbering error, decreasing channel number sequence
Unit number (from TN)
ISL Channel number
0
24
1
23
2
22
3
21
4
20
5
19
6
18
7
17
Nortel Communication Server 1000