70. Calls queued to an attendant via direct dial to an attendant VDN were left in 
queue and could not be answered.
71. If all preferences of a routing pattern with Look Ahead Routing (LAR) 
enabled were busy for a data call over an ISDN PRI trunk, DEFINITY 
returned Cause #58 (Bearer Capability Not Presently Available), and 
Cause #58 did not trigger LAR.
72. The command “list bridge” aborted when a bridged appearance was on a 
station that was unmerged, and then its former port was reused by another 
station.
73. After unregistering from the Roadwarrior application, an immediate phone 
call on the previously associated extension would be dropped. 
74. Not all TN793 ports returned to service after an upgrade. 
75. For G3si systems with Duplex Switch Processing Element (SPE) and Tone 
Clocks (TC) in the Processor Port Network, if both the active SPE and the 
TC were in carrier “A”, the standby SPE was in standby mode, and “A” 
carrier power supply was lost, then a spontaneous WARM restart SPE 
interchange would occur.  However, the TC would not be interchanged 
automatically.  The interchange required manual intervention to bring the 
dial tone back (or a wait of up to an hour for background maintenance to 
detect and correct the problem).
Now, during the spontaneous WARM restart SPE interchange, if the TC 
must be switched to the “B” carrier, then the “B” carrier is selected and the 
system performs a COLD2 (“Tone Clock Loss”) restart to automatically 
correct the problem.
76. The Advice-of-Charge (AOC) station display did not clear after an outgoing 
ISDN trunk call was dropped.  The AOC display is now cleared 10 seconds 
after the call is dropped. 
77. On certain ISDN offnet coverage and forwarding calls, the call rang 
continuously and did not return to a subsequent coverage point. 
78. H.323 IP trunk Station Message Detail Recording (SMDR) records 
indicated that calls dropped locally even when the trunk side dropped first.  
Also, H.323 IP trunks dropped slowly under timer-expiration/error-log 
scenarios. 
79. An endpoint registration using a non-Lucent application without an 
extension number may have caused a system reset.  The registration is 
now rejected.
80. If a user had no administered entries in the change node-names form, but 
then administered a VDN, and on page 2 pressed “HELP” in either the 
Audix Name or the Messaging Server Name fields, the System Access 
Terminal (SAT) logged off.
81. Certain displays potentially caused system resets.
82. An Expert Agent Selection (EAS) agent on a physical station with console 
permissions was blocked from forwarding another station.