Multicarrier G2 Universal Module to R8r EPN 
5-93
Critical Reliability 
5
For 2 Collocated Expansion Port Networks
1. Behind control carrier A of PPN cabinet 1:
Install a lightwave transceiver on the cable connector at slot 1A02.
Connect a fiber optic cable to the transceiver just installed.
Carefully attach the fiber optic cable (with cable ties) to the wall of 
the cable tray at the built-in cable tie positions.
2. Behind control carrier A of EPN cabinet 3:
Install a lightwave transceiver on the cable connector at slot 3A01.
Connect the other end of the fiber cable to the transceiver just 
installed.
Carefully attach the fiber optic cable (with cable ties) to the wall of 
the cable tray at the built-in cable tie positions.
At the top of the cabinet, coil up the surplus fiber optic cable and 
attach it to the wall of the cable tray.
3. Behind control carrier B of PPN cabinet 1:
Install a lightwave transceiver on the cable connector at slot 1B02.
Connect a fiber optic cable to the transceiver just installed.
Carefully attach the fiber optic cable (with cable ties) to the wall of 
the cable tray at the built-in cable tie positions.
4. Behind port carrier B of EPN cabinet 3:
Install a lightwave transceiver on cable connector at slot 3B02.
Connect the other end of the fiber optic cable to the lightwave 
transceiver, just installed, at slot 3B02.
Carefully attach the fiber optic cable (with cable ties) to the wall of 
the cable tray at the built-in cable tie positions.
At the top of the cabinet, coil up the surplus length of fiber optic 
cable, and carefully attach the coil to the wall of the cable tray.
5. Behind control carrier A of EPN cabinet 2:
Install a lightwave transceiver on cable connector at slot 2A02.
Connect 1 end of the fiber optic cable to the lightwave transceiver, 
just installed, at slot 2A02.
Carefully attach the fiber optic cable (with cable ties) to the wall of 
the cable tray at the built-in cable tie positions.