Lucent Technologies 555-233-115 ユーザーズマニュアル
DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r
Upgrades and Additions for R8r
555-233-115
Issue 1
April 2000
Adding or Removing Cabinet Hardware
6-89
Add a Control Carrier (Add Duplication)
6
Figure 6-31.
TDM/LAN Connections for High-Reliability PPN
9. Connect the loose end of the TDM/LAN cable (between the “A” and “B”
carriers) to the pin-field block marked “TDM/LAN” on the left side of the
“B” carrier (See
“B” carrier (See
and
). The other end remained
connected to the “A” carrier when the old carrier was removed.
CONTROL CARRIER
SLOT 21
B
A
D
PORT CARRIER
PORT CARRIER
SLOT 21
CONTROL CARRIER
TDM/LAN BUS
TERMINATOR
SLOT 21
E
(ZAHF4)
SLOT 21
C
REAR VIEW
PORT CARRIER
(ZAHF4)
SLOT 21
J58890AP-1
J58890BB
J58890AP-1
J58890BB
J58890BB
SEE NOTE
SEE NOTE
SLOT 01
SEE NOTE
NOTE:
ON PORT CARRIER J58890BB-1, CONNECT THE TDM/LAN CABLE OR TDM/LAN TERMINATOR TO
SLOT 02. ON PORT CARRIERS J58890BB-2 AND -3, CONNECT THE TDM/LAN CABLES TO SLOT 01.
SLOT 00
TDM/LAN BUS TERMINATOR
TDM/LAN CABLE
WP91716 L6
TDM/LAN CABLE
WP91716 L7
TDM/LAN CABLE
WP91716 L6
TDM/LAN CABLE
WP91716 L6