Fiber Link Administration 
A-6
Administer Fiber Links 
A
d. The 
DS1CONV Board Type
: field is display only and shows the 
type of DS1 Converter circuit pack in Endpoint-1. The circuit pack 
type in Endpoint-1 (A-PNC) and Endpoint-1 (B-PNC) must match.
e. In the 
Is one endpoint remoted via a DS1 Converter 
Complex?
 field, type y to specify that a DS1 Converter complex is 
used to remote 1 endpoint. If is entered, administer the A-PNC 
DS1 Converter Board Location on Page 1. The A-PNC DS1 
Converter Board Type displays.
7. On Page 2 of the form:
a. Administer the A-PNC DS1 Converter (DS1CONV) Attributes.
b. Enter the DS1 Converter Facilities information. In the 
Facility 
Installed?
 field, type y for all installed facilities (A, B, C, and D).
c. In the 
Bit Rate
:
 field, type 1.544 for T1 operation or 2.048 for E1 
operation. 
NOTE:
One bit rate applies for all facilities within the same DS1 
Converter complex. The 
Bit Rate:
 field displays only under 
Facility A.
d. Enter the idle code in the 
Idle Code MSB (1) . . . . LSB 
(8):
 field. The default value is 11101000. It is recommended that 
the default value be used unless it becomes absolutely necessary 
to change it. The “MSB” means Most Significant Bit, the “LSB” 
means Least Significant Bit. 
e. Enter the appropriate data in the 
Line Coding: 
field. This data 
should match the line coding of the facility. For T1, example line 
coding is b8zs. For E1, example line coding is hdb3
f. Scroll to Page 3 and modify the fields as needed for the B-PNC.
NOTE:
If this data is not correct, wideband errors (such as 
multimedia call handling) may occur. 
8. For T1 sites, refer to 
. For E1 sites, refer to 
.