Lucent Technologies 555-233-115 ユーザーズマニュアル
DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r
Upgrades and Additions for R8r
555-233-115
Issue 1
April 2000
Adding or Removing Cabinet Hardware
6-133
Add MCC Port Carriers
6
4. Type first-only in this field to enable Alarm Origination (to the first OSS,
which should be INADS).
Be sure to type y in both
Cleared Alarm Notification
and
Restart
Notification
fields. Press
Enter
.
NOTE:
The INADS Database Administrator enables Alarm Origination as
part of the registration process.
part of the registration process.
!
CAUTION:
If you do not enable Alarm Origination when the customer has
purchased a services contract, the switch will not report any alarm to
the TSC automatically, causing the TSC to be unable to fulfill the
services contract.
purchased a services contract, the switch will not report any alarm to
the TSC automatically, causing the TSC to be unable to fulfill the
services contract.
Save Translations
1. If the system is high- or critical-reliability, type status spe and press
Enter
to verify that the standby SPE is refreshed and that the standby disk is in
service.
service.
2. Type save translation [spe-a or both] disk and press
Enter
. This
command instructs the system to take all translation information in
memory and write it to the disk(s).
memory and write it to the disk(s).
3. If the MCC port network contains a TN750 Announcement circuit pack,
type list configuration software-version and press
Enter
.
If screen 2 shows that recorded announcements were saved, these
announcements can be restored using the restore announcements
command. Type restore announcements and press
announcements can be restored using the restore announcements
command. Type restore announcements and press
Enter
.
4. Type backup disk [spe-a or both] and press
Enter
. This command
instructs the system to backup the current information on disk to the
removable media.
removable media.