DEFINITY Enterprise Communications Server  Release 6
Maintenance for R6vs/si  
555-230-127   
Issue 1
August 1997
Maintenance Object Repair Procedures 
Page 10-391
DETR-BD 
10
DETR-BD
G1, G3iV1.1-286, and those G3iV2-386 systems that use the Mu-law 
companding mode use TN748 Tone Detector circuit packs or TN756 
combination Tone Detector-Tone-Clock circuit packs. G3iV2-386 systems that 
use the A-Law companding mode use TN420B (and higher suffixes) Tone 
Detector circuit packs. The companding mode of the DETR-BD circuit pack must 
match that administered for the system for proper tone detection. The 
companding mode is administered on the System-Parameters Country-Options 
form. Refer to 
DEFINITY Communications System Generic 3 Implementation
555-230-653.
For all DETR-BD circuit pack level errors, refer to XXX-BD (Common Port Board) 
Maintenance documentation.
1.
Where P is the port network number (1 for PPN, 2 for EPN, and 3 for EPN2); C is the carrier 
number (for example, A, B, C, D, or E); SS is the address of the slot in the carrier where the circuit 
pack is located (for example, 01, 02, ..., etc.).
MO Name (in 
Alarm Log)
Alarm Level
Initial Command to 
Run
1
Full Name of MO
DETR-BD
MINOR
test board PCSS
Tone Detector Circuit Pack
DETR-BD
WARNING
test board PCSS
Tone Detector Circuit Pack