Lucent Technologies lucent ユーザーズマニュアル

ページ / 2392
DEFINITY Enterprise Communications Server  Release 6
Maintenance for R6vs/si  
555-230-127   
Issue 1
August 1997
Maintenance Object Repair Procedures 
Page 10-407
DID-TRK (DID Trunk) 
10
Additional in-line testing is performed while a call is in progress. Thus, in-line 
errors may occur during operation. See Error Log table for a description of these 
errors. These errors may be reproduced by using the trunk (that is, placing a call) 
and checking their occurrence in the Hardware Error Log.
Problems detected during signaling may be caused by faults off-board (in the 
CO switch or connections) for which a Warning alarm is raised.
Before a maintenance test can be run on a port, the port must be idle. If an 
incoming call seizes the port which is being tested by maintenance, the test is 
aborted, and the incoming call proceeds.
For transmission and signaling standard specification, refer to Digital PBX 
Standards document RS4648.
Hardware Error Log Entries and Test to Clear 
Values
Table 10-132.
DID Trunk Error Log Entries 
Error 
Type
Aux 
Data
Associated Test
Alarm 
Level
On/Off 
Board
Test to Clear Value
0
1
0
Any
Any
Any
test port PCSSpp sh r 1
1 (a)
Any
None
WRN
OFF
1 (b)
57476
None
WRN
OFF
1 (c)
57477
None
WRN
OFF
1 (d)
57483
None
WRN
OFF
15 (e)
Any
Port Audit Update 
(#36)
18
0
busyout trunk 
<grp/mbr>
WRN
OFF
release trunk <grp/mbr>
130 (f)
None
WRN
ON
test trunk <grp>/<mbr>
257 (g)
57472
None
WRN
OFF
257 (h)
57473
None
WRN
OFF
257 (i)
57474
None
WRN
OFF
257 (j)
57475
None
WRN
OFF
513 (k)
57392
None
MAJ/MIN/ 
WRN
2
OFF
510 (l)
57393
None
769
Any
Port Diagnostic 
(#35)
MAJ/MIN/ 
WRN
ON
test port PCSSpp r 3
Continued on next page