DEFINITY Enterprise Communications Server  Release 6
Maintenance for R6vs/si  
555-230-127   
Issue 1
August 1997
Routine Maintenance Procedures 
Page 5-8
Restoring Power 
5
contain an Expansion Interface circuit pack that is part of the Active 
Expansion Link or an Active Tone-Clock. To determine which Expansion 
Interface Link and Tone-Clock are active, issue the 
status system
 
command. To determine the synchronization reference, use the 
display 
synchronization
 command.
1. To restore power to the cabinet:
NOTE:
If the cabinet is powered by a 676B Power Unit, the 676B must have 
been powered off for at least 10 seconds before being powered on. 
If not, the 676B Power Unit does not restart.
In an AC-Powered single-carrier cabinet system, turn on the power 
in each cabinet individually. The ON/OFF switch is located at the 
back of the cabinet behind the WP-91153 Power Unit.
In a DC-Powered single-carrier cabinet system, turn on the power 
in each cabinet individually. The ON/OFF switch is located at the 
back of the cabinet behind the 676B Power Unit.
2. The EPN circuit packs is inserted and the EPN is available for call 
processing.
3. After the system reboot is finished and all trouble is cleared, return the 
Emergency Transfer switch to AUTO. This restores the system to the 
normal operating mode.
Power Up the AUDIX System
1. Using a pointed object such as a paper clip or a pen (do not use a pencil), 
press the Boot/Shutdown button.
2. Hold the boot/Shutdown button in until the display indicates the message, 
BTEST
, steady on.
3. Release the Boot/Shutdown button. the DEFINITY AUDIX system takes 
approximately 5 minutes to power up.
The display has the following sequence of steady on messages:
— OSINIT
— OS
— AINIT
— ADX
The DEFINITY AUDIX System is now powered up. When the system 
is in the active state, the display indicates 
ADX
, and the red LED is 
off.