DEFINITY Enterprise Communications Server  Release 6
Maintenance for R6vs/si  
555-230-127   
Issue 1
August 1997
Maintenance Object Repair Procedures 
Page 10-417
DID-TRK (DID Trunk) 
10
Port Diagnostic Test (#35)
This test checks a port’s battery feed circuitry. The battery feed circuitry is tested 
for on-/off-hook detection, battery shutdown, and battery reversal (WINK) 
capabilities.
0
NO 
BOARD
The test could not relate the internal ID to the port (no board).
1. Check to ensure that the board translations are correct. Translate the 
board, if necessary.
2. Issue the 
busyout board
 command.
3. Issue the 
reset board
 command.
4. Issue the 
release busy board
 command.
5. Issue the 
test board
 command. This should re-establish the linkage 
between the internal ID and the port.
Table 10-135.
TEST #35 Port Diagnostic Test 
Error 
Code
Test 
Result
Description/ Recommendation
ABORT
System resources required to run this test were not available.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2. If the test continues to abort, escalate the problem.
Continued on next page
Table 10-134.
TEST #33 Loop Around and Conference Circuit Test  — 
Continued
Error 
Code
Test 
Result
Description/ Recommendation
Continued on next page