Lucent Technologies lucent ユーザーズマニュアル

ページ / 2392
DEFINITY Enterprise Communications Server  Release 6
Maintenance for R6vs/si  
555-230-127   
Issue 1
August 1997
Maintenance Object Repair Procedures 
Page 10-441
DIG-LINE (Digital Line) 
10
Voice and Control Channel Local Loop Test (#13)
These tests check the information and control channels between the Switch 
Processing Element (SPE) and the Digital Line port circuit. The SPE sends a 
message to loop around both the information and control channels for the port. 
Table 10-144.
TEST #11 Digital Line Electronic Power Feed Test
Error 
Code
Test 
Result
Description/ Recommendation
ABORT
Internal System Error
1. Retry the command at 1-minute intervals a maximum of 5 times.
2. If the test continues to abort, escalate the problem.
1000
ABORT
System resources required to run this test are not available. The port may 
be busy with a valid call. Use 
display port PCSSpp
 to determine the 
station extension or attendant number of the port. Use 
status station
 or 
status attendant
 to determine the service state of the port. If the service 
state indicates that the port is in use, then the port is unavailable for certain 
tests. (See Chapter 10, "Maintenance Commands and Trouble-Clearing 
Aids", for a full description of all possible states.) You must wait until the 
port is idle before retesting. Attendants are always in use (off-hook) if the 
handset is plugged in and the port is not busied out.
1. If the port status is idle, then retry the command at 1-minute intervals a 
maximum of 5 times.
2. If the test continues to abort, escalate the problem.
FAIL
Internal System Error
1. Retry the command at 1-minute intervals a maximum of 5 times.
2. If the test continues to abort, escalate the problem.
PASS
Electronic Power Feed Test passed. The message to turn on the power to 
the station was successfully sent to the port.
1. Although this test will never actually return a FAIL result except for the 
Internal System Error (naught/FAIL ) described above, it will log an 
error indicating the real results of the test. Check the Error Log for any 
entries with Error Types 767 or 769 after the test completes.
2. If Error Type 767 appears in the Error Log, this should indicate that the 
test sensed no problems with the power to the station. To verify that the 
station is powered up correctly, run a self-test on the station, if 
available, and check that all the feature buttons are operating.
3. If Error Type 769 appears in the Error Log, this indicates some problem 
with the power to the station. Check for a short in the wiring, a 
damaged jack, a defective voice terminal, or an incorrect type of 
terminal.
Continued on next page