Maintenance Object Repair Procedures 
Page 10-446
DIG-LINE (Digital Line) 
10
Digital Station Audits Test (#17)
This is a series of six tests which are classified as audits. The SPE sends 
messages to the on-board microprocessor to perform the following tests. These 
audits run only if the station is in-service.
Switchhook Inquiry Test 
 This is an update of the SPE records 
according to the circuit pack’s records. This inquiry is sent all the way to 
the voice terminal.
Bad Scan Inquiry Test 
 A message is sent uplink which contains a 
count that is generated due to certain events relating to the link conditions. 
This can be an indication of communications problems between the 
Processor and Digital Port circuit pack.
EPF/PTC Inquiry Test 
 For a TN413 or a TN754 vintage 13 or earlier, the 
status of the Electronic Power Feed (EPF) is sent uplink. Possible 
conditions are: EPF-on-ok, EPF-off, and EPF-no-load. For TN754 vintage 
14 or later, TN754B or TN2136, TN2181, TN2224, the status of the Positive 
Temperature Coefficient (PTC) is sent uplink. Possible conditions are: 
PTC-on-ok, PTC-off, and PTC-no-load.
ID Request Test 
 A request is made to the station for its status. The 
station sends its configuration information and health information back. 
This information is checked and a pass/fail result is provided.
Ringer Update Test 
 This updates the digital telephone ringer state 
according to the processor records.
FAIL
Internal System Error
1. Retry the command at 1-minute intervals a maximum of 5 times.
2. If the test continues to abort, escalate the problem.
PASS
The message to light all of the station lamps was sent successfully to the 
port.
1. Observe the station lamps being lit when running the test. If all lamps 
do not light successfully, the other Digital Line test results may 
indicate related problems that will not allow the lamps to light.
2. Investigate by using other Digital Line port tests, and by examining the 
station, wiring, and connections.
Table 10-146.
TEST #16 DIG-LINE Station Lamp Updates Test  — 
Continued
Error 
Code
Test 
Result
Description/ Recommendation