Lucent Technologies lucent ユーザーズマニュアル

ページ / 2392
DEFINITY Enterprise Communications Server  Release 6
Maintenance for R6vs/si  
555-230-127   
Issue 1
August 1997
Maintenance Object Repair Procedures 
Page 10-451
DIOD-DS1 (DS1 DIOD Trunk) 
10
Three trunk service states are specified by DS1 DIOD trunk maintenance:
Hardware Error Log Entries and Test to Clear 
Values
out-of-service
The trunk is in a deactivated state and 
cannot be used for either incoming or 
outgoing calls.
in-service
The trunk is in an activated state and can 
be used for both incoming and outgoing 
calls.
disconnect (ready-for-service)
The trunk is in an activated state but can 
only be used for an incoming call.
Table 10-148.
DS1 DIOD Error Log Entries 
Error 
Type
Aux 
Data
Associated Test
Alarm 
Level
On/Off 
Board
Test to Clear Value
0
1
0
Any
Any
Any
test trunk <grp>/<mbr>
1(a)
57408
1(a)
57487 
57476 
57477 
57485
15(b)
Any
Port Audit and 
Update Test (#36)
18(c)
0
busyout trunk 
<grp>/<mbr>
WARNING
OFF
release trunk <grp>/<mbr>
130(d)
None
WARNING
ON
test trunk <grp>/<mbr>
257(e)
57392
DS1 CO Dial Tone 
Seizure Test (#314)
MIN/MAJ
2
OFF
513(f)
57393
DS1 Tie Trunk 
Seizure Test (#136)
MIN/MAJ
2
OFF
769(g)
57484
1025(h)
51200
1025
DS1 CO Dial Tone 
Seizure Test (#314)
MIN/
WRN
3
OFF
test trunk <grp>/<mbr> r 2
1281
Conference Circuit 
Test (#7)
MIN/
WRN
3
ON
test trunk <grp>/<mbr> l r 4
1537
NPE Crosstalk Test 
(#6)
MIN/
WRN
3
ON
test trunk <grp>/<mbr> l r 3
1793(i)
test board PCSS l
Continued on next page