Lucent Technologies lucent ユーザーズマニュアル
DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-549
DTMR-PT [Dual Tone Multifrequency Port (TTR)]
10
Hardware Error Log Entries and Test to Clear
Values
Values
Notes:
a. There are two possible alarm levels for this error: Major alarm and Minor
alarm. A Major alarm is raised if the total number of DTMR ports currently
in service is less than or equal to one half of the administered threshold
number. Otherwise, a Minor alarm is raised. In either case, run the Short
Test Sequence against the DTMR port and follow the error code
procedures for the individual tests.
in service is less than or equal to one half of the administered threshold
number. Otherwise, a Minor alarm is raised. In either case, run the Short
Test Sequence against the DTMR port and follow the error code
procedures for the individual tests.
The threshold number of DTMR ports for service is administered using the
change system-parameters maintenance
command.
b. This error indicates the DTMR port is having problems detecting
touch-tone digits. If this error is being constantly logged, then the Tone
Detector circuit pack containing the defective DTMR port should be
replaced.
Detector circuit pack containing the defective DTMR port should be
replaced.
c. The DTMR port lost its translation. Testing the DTMR port is sufficient to
reload its translation. If testing the DTMR port does not clear the error,
then the Tone Detector circuit pack containing the defective DTMR port
should be replaced.
then the Tone Detector circuit pack containing the defective DTMR port
should be replaced.
d. This error type indicates that the circuit pack has been removed or has
been insane for at least 11 minutes. To clear the error, reinsert or replace
the circuit pack.
the circuit pack.
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
appropriate test description and follow the recommended procedures.
Dual Tone Multifrequency Receiver Port (TTR) Error Log Entries
Error
Type
Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
0
1
0
Any
Any
Any
test port PCSSpp sh r 1
1 (b)
17664
Tone Detector
Audit/Update Test
(#43)
Audit/Update Test
(#43)
MAJOR/
MINOR (a)
MINOR (a)
ON
test port PCSSpp r 2
18
0
busyout port PCSSpp
WARNING
ON
release port PCSSpp
130 (d)
None
WARNING
ON
test port
PCSSpp sh r 2
257 (c)
17666
Tone Detector
Audit/Update Test
(#43)
Audit/Update Test
(#43)
MAJOR/
MINOR (a)
MINOR (a)
ON
test port PCSSpp r 3
513
Any
Tone Detection
Verification Test (#42)
Verification Test (#42)
MAJOR/
MINOR (a)
MINOR (a)
ON
test port PCSSpp r 3