Lucent Technologies lucent ユーザーズマニュアル

ページ / 2392
DEFINITY Enterprise Communications Server  Release 6
Maintenance for R6vs/si  
555-230-127   
Issue 1
August 1997
Maintenance Object Repair Procedures 
Page 10-570
E-DIG-BD (Multi Application Platform Board) 
10
E-DIG-BD (Multi Application 
Platform Board)
The maintenance strategy for DIG800-BD is the same as the one described for 
MO-COMBD (MO-XXX-BD). Maintenance testing of the common circuit pack is 
handled by on-board firmware and SPE controlled tests. Maintenance software 
queries the firmware for error and alarm information, status, and test results. The 
firmware automatically reports error conditions that will result in SPE-controlled 
testing.
Board Insertion
The switch makes an additional board query if any of the following circuit packs 
are inserted:
For any of the above initial board up-links, the switch sends queries requesting 
additional data from the board for administration purposes, while also telling the 
board the switch software release and the system type.
For the native mode, the response to the board query downlink messages 
consists of several CCMS uplink messages that identify the true board code, 
vintage, suffix, emulation type, and the number of reserved slots it needs.
1.
Where P is the port network number (1 for PPN and 2 or 3 for EPN); C is the carrier 
designation (for example, A, B, C, or D); and SS is the address of the slot in the carrier 
where the circuit pack is located (for example, 01, 02, ...).
MO Name (in 
Alarm Log)
Alarm 
Level
Initial Command to Run
1
Full Name of MO
DIG800-BD
MIN
test board PCSS sh
MO800DIG-BD
DIG800-BD
WRN
test board PCSS sh
MO800DIG-BD
Circuit Pack
Vintage
TN754
49
TN556
49,
80 or greater
TN800
any