Lucent Technologies lucent ユーザーズマニュアル

ページ / 2392
DEFINITY Enterprise Communications Server  Release 6
Maintenance for R6vs/si  
555-230-127   
Issue 1
August 1997
Maintenance Object Repair Procedures 
Page 10-594
ETR-PT (Enhanced Tone Receiver Port) 
10
at a time when it is convenient to remove a clock board from the system. 
Follow the procedures described in the TONE-BD section for replacing a 
tone/clock circuit pack.
System Technician-Demanded Tests: 
Descriptions and Error Codes
Always investigate tests in the order presented in the following tables when 
inspecting errors in the system. By clearing error codes associated with the 
Tone 
Detection Verification Test
, for example, you may also clear errors generated 
from other tests in the testing sequence.
Tone Detection Verification Test (#42)
This test checks out a single ETR port in the touch-tone receiver mode MFC tone 
detection/generation mode and general purpose tone detection mode. During 
the first portion of the test, the touch-tone receiver mode is tested. Then general 
purpose call progress and maintenance tones are tested and lastly MFC tones 
are tested.
1.
D = Destructive; ND = Nondestructive
Order of Investigation
Short Test 
Sequence
Long Test 
Sequence
D/ND
1
Tone Detection Verification Test (#42)
X
X
ND
Tone Detection Audit/Update Test (#43)
X
X
ND
Table 10-205.
TEST #42 Tone Detection Verification Test 
Error 
Code
Test 
Result
Description/ Recommendation
none
ABORT
The system was not able to allocate all the resources needed for this test 
OR there was an Internal System Error.
1
ABORT
The system could not allocate all the resources needed to test the tones.
1001
ABORT
The system was unable to put the ETR-PT in the appropriate mode to test 
it.
Continued on next page