Maintenance Object Repair Procedures 
Page 10-598
EXP-INTF (Expansion Interface Circuit Pack) 
10
EXP-INTF (Expansion Interface 
Circuit Pack)
!
CAUTION:
A detailed flowchart for isolating and resolving Packet Bus faults is included 
in Chapter 9, "Packet Bus Fault Isolation and Correction". This flowchart, 
along with the other information presented in the chapter, can help in 
resolving problems relevant to the Packet Path of the TN570 Expansion 
Interface. Whenever the repair procedures for this Maintenance Object 
refer to Packet Bus and/or Packet Control maintenance, be sure to 
reference Chapter 9, "Packet Bus Fault Isolation and Correction" in addition 
to the relevant MO documentation.
The TN570 or the TN776 Expansion Interface circuit pack is used to provide 
connectivity between the Processor Port Network (PPN) and either Expansion 
Port Network (EPN) (network 2 or 3) or between the two Expansion Port 
Networks. The TN776 Expansion Interface is used in G1 systems to provide 
connectivity between the Processor Port Network and the (single) Expansion Port 
Network. This connectivity is provided via a 32 Mbps fiber optic cable. The 
TN776 supports circuit-switched connections and the control channel to and 
from the EPN. The TN570 also supports packet-switched connections for those 
systems that use the Packet Bus. The TN776 and TN570 circuit packs must only 
be used in matched pairs. A TN776 circuit pack does not function if connected 
via fiber to a TN570 circuit pack and vice versa.
The EPN(s), if present, are always under the control of the TN777 Processor 
circuit pack in the PPN. Therefore, if the Expansion Interface circuit packs to the 
EPN are not functioning correctly, service may be unavailable in that EPN, but is 
available in the PPN. If the Expansion Interface circuit packs between EPNs are 
not functioning properly, there is service in all networks, but connectivity between 
EPN and EPN is not available.
A system with EPN(s) may have one or two pairs of Expansion Interface circuit 
packs connecting any two cabinets. If two pairs exist, one pair operates as the 
Active pair and provides the required connectivity. The second pair acts as a hot 
1.
Where P is the port network number 1, 2, or 3, C is the carrier designation (for example, A, B, C, 
or D); and SS is the address of the slot in the carrier where the circuit pack is located (for example, 
01, 02, ..., and so forth).
MO Name (in 
Alarm Log)
Alarm 
Level
Initial Command to Run
1
Full Name of MO
EXP-INTF
MAJOR
test board PCSS sh
Expansion Interface Circuit Pack
EXP-INTF
MINOR
test board PCSS sh
Expansion Interface Circuit Pack
EXP-INTF
WARNING
test board PCSS sh
Expansion Interface Circuit Pack