DEFINITY Enterprise Communications Server  Release 6
Maintenance for R6vs/si  
555-230-127   
Issue 1
August 1997
Maintenance Object Repair Procedures 
Page 10-601
EXP-INTF (Expansion Interface Circuit Pack) 
10
which contains this Expansion Interface circuit pack is in-service (up), the 
Expansion Interface circuit pack is active; if it is out-of-service (down), the 
Expansion Interface circuit pack is neither active nor standby.
e. This is the normal state for a Standby Expansion Interface circuit pack. It is 
also the state of the TN570 Expansion Interface circuit pack immediately 
after circuit pack initialization when the system has not yet assigned a role 
to it (that is, Active or Standby). To distinguish between these two 
situations, use the 
status system
 command. If the link which contains this 
Expansion Interface circuit pack is in-service (up), the Expansion Interface 
circuit pack is standby; if it is out-of-service (down), the Expansion 
Interface circuit pack is neither active nor standby.
When testing Expansion Interface circuit packs to investigate problems, tests 
should always be run on both circuit packs of an Expansion Link. This provides a 
better indication of where a problem is located. Hardware errors for all Expansion 
Interface circuit packs (EXP-INTF) may be displayed by using the category "infc" 
on the Display Errors form.
In the EPN, the EPN TN775 Maintenance (MAINT) circuit pack monitors the sanity 
of the Expansion Interface circuit pack. If the Expansion Interface circuit pack 
should cycle between sane and insane several times, the Maintenance circuit 
pack holds the Expansion Interface circuit pack reset. If a new Expansion 
Interface circuit pack is installed in the EPN, the EPN Maintenance circuit pack 
should be removed because it may attempt to hold the new Expansion Interface 
circuit pack reset. The Maintenance circuit pack may be reinstalled after the 
Expansion Interface circuit pack has been inserted and the Expansion Interface 
circuit pack’s red LED has gone off.
The Active Expansion Link is also involved in synchronization between the two 
cabinets. The Expansion Interface circuit pack reports slip errors if the two 
cabinets are not correctly synchronized. When diagnosing synchronization 
problems, the Expansion Interface circuit packs should be examined as a 
possible cause.
Relationship Between Expansion Interface and 
Tone-Clock Circuit Packs
The Expansion Interface fiber link depends on the system clock that is provided 
by the Active Tone-Clock circuit pack on each network. (See TDM-CLK and 
TONE-BD Maintenance documentation.) Each Expansion Interface circuit pack 
transmits over the fiber at a rate derived from the system clock on its network. If 
the Active Tone-Clock is defective to the point where the system clock frequency 
it produces is out of the specified range ("out of spec"), an Expansion Interface 
Link might go down even though the Expansion Interface circuit packs are 
healthy. In a High or Critical Reliability system, both links could go down if there 
is a defective Active Tone-Clock.