Lucent Technologies lucent ユーザーズマニュアル

ページ / 2392
DEFINITY Enterprise Communications Server  Release 6
Maintenance for R6vs/si  
555-230-127   
Issue 1
August 1997
Maintenance Object Repair Procedures 
Page 10-638
EXP-INTF (Expansion Interface Circuit Pack) 
10
Expansion Interface Packet Interface Test (#589)
This test attempts to send a data packet from the TN778 Packet Control circuit 
pack through any intervening Expansion Interface circuit packs and through the 
Expansion Interface circuit pack to be tested. The path the data packet takes is 
dependent on the location of the Expansion Interface circuit pack to be tested 
and whether the Expansion Interface circuit pack is par of the Active link or 
Standby link.
5016 
5017 
5018 
5019 
5032 
5033 
5048 
5064 
5080 
5096 
5112
FAIL
Initialization failure:
 Expansion Interface circuit pack reset successfully 
and restarted execution. But the Expansion Interface circuit pack detected 
communication errors during the self-test phase of the hardware 
initialization. The nature of the failure may prevent the Expansion Interface 
circuit pack from communicating with its neighbor Expansion Interface 
circuit pack on the opposite end of the fiber. The fault itself may be either 
on the Expansion Interface circuit pack or on the lightwave transceiver.
1. If all other tests on this Expansion Interface circuit pack are passing 
and no other errors have been logged against this circuit pack, 
replacement of the lightwave transceiver or the circuit pack are 
recommended, but not critical.
2. If all other tests on this Expansion Interface circuit pack are not 
passing or other errors have been logged against this circuit pack, the 
lightwave transceiver and/or the Expansion Interface circuit pack 
should be replaced.
PASS
The Expansion Interface was successfully reset, and it did restart 
execution. Also, it passed all its initialization tests and detected a lightwave 
transceiver. Remove the Expansion Interface circuit pack from the busyout 
state by using the 
release board PCSS
 command.
1. Execute 
test board PCSS short
 command. Refer to errors for each 
test.
0
NO 
BOARD
No board was detected by the test.
1. Check the error log for wrong board (error 125) or no board (error 131). 
Resolve either of these issues, if applicable.
2. Check that the board is properly translated and inserted. If so, check 
for hyperactivity (error 1538). If hyperactive, use the 
reset board 
PCSS 
command.
3. Run the test again. If it fails, the ID chip on board may be bad. Replace 
the board and retest.
Table 10-215.
TEST #336 Expansion Interface Reset Test  — 
Continued
Error 
Code
Test 
Result
Description/ Recommendation
Continued on next page