Maintenance Object Repair Procedures 
Page 10-657
FL-DATA (Flash Data Consistency) 
10
FL-DATA (Flash Data Consistency)
In systems with high or critical reliability, the software and the hard patch update 
files are stored in the on-board flash memory in both the Active SPE and Standby 
SPE. The translations and announcements are stored in the memory cards in 
both the Active SPE and Standby SPE. Flash Data Consistency flags problems 
when files become mismatched by monitoring the translations, announcements, 
update files, and software vintage number in a High or Critical Reliability PPN 
system. If the software vintage numbers on both SPEs are mismatched, a 
MAJOR alarm is raised. If the announcement files on both memory cards are 
mismatched, a WARNING alarm is raised. For all other problems, a MINOR alarm 
is raised. The software vintage can be displayed via the 
list configuration 
software-vintage long
 command. The Flash Data Consistency Test is run on 
system technician command and as part of daily Standby SPE maintenance.
NOTE:
Flash Data Consistency is not applicable to Standard systems.
Error Log Entries and Test to Clear Values
MO Name (in 
Alarm Log)
Alarm Level
Initial Command to 
Run
Full Name of MO
FL-DATA
MAJOR
test card-mem a|b l
 Flash Data Consistency
FL-DATA
MINOR
test card-mem a|b l
 Flash Data Consistency
FL-DATA
WARNING
test card-mem a|b l
 Flash Data Consistency
Table 10-222.
Flash Data Consistency Error Log Entries 
Error 
Type
Aux 
Data
Associated Test
Alarm 
Level
On/Off 
Board
Test to Clear Value
0
1
0
Any
Any
Any
test card-mem a/b l
8 or 16
8 or 16
Flash Data Consistency 
Test (#421)
WNG
OFF
test card-mem a/b
1-3,
9-10,
17-18,
32-34,
40-42,
48-50,
Continued on next page