Lucent Technologies lucent ユーザーズマニュアル

ページ / 2392
DEFINITY Enterprise Communications Server  Release 6
Maintenance for R6vs/si  
555-230-127   
Issue 1
August 1997
Maintenance Object Repair Procedures 
Page 10-676
HYB-LINE (Hybrid Line) 
10
When the 
status station
 command has been run, and the status screen 
appears, the status is reported as either out-of-service or in-service, which mean 
exactly as stated in the above list, or disconnect, which means the station is in 
the ready-for-service state.
Hardware Error Log Entries and Test to Clear 
Values
Notes:
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the appropriate 
test description and follow the recommended procedures.
2.
Major or Minor alarms on this MO may be downgraded to Warning alarms based on the values used in 
the 
set options
 command.
Table 10-224.
Hybrid Line Error Log Entries 
Error 
Type
Aux 
Data
Associated Test
Alarm 
Level
On/Off 
Board
Test to Clear Value
0
1
0
Any
Any
Any
test port PCSSpp sh r 1
1 (a)
Any
None
WARNING
OFF
15 (b)
Any
Hybrid Audits Test 
(#61)
18 (c)
0
busyout port 
PCSSpp
WARNING
OFF
release port PCSSpp
130 (d)
None
WARNING
ON
test port PCSSpp sh
257 (e)
40988
None
MIN/WRN
2
OFF
513 (f)
40965
Hybrid Line Audits 
Test (#61)
WARNING
OFF
test port PCSSpp sh r 4
769 (g)
Remote Dig Loop 
Around Test (#59)
WARNING
OFF
test port PCSSpp sh r 3
1025
Hybrid & Conf. 
Circuits Test (#57)
MIN/WRN
2
ON
test port PCSSpp l r 3
1281 (h)
Local Digital Loop 
Around Test (#58)
WARNING
ON
test port PCSSpp l r 3
1537 (i)
40968
None
WARNING
OFF
1793
TDMNPE Crosstalk 
Test (#6)
MIN/WRN
2
ON
test port PCSSpp l r 3
2049 (j)
32770
None
2049 (k)
40967
None
Continued on next page