Lucent Technologies lucent ユーザーズマニュアル
DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-676
HYB-LINE (Hybrid Line)
10
When the
status station
command has been run, and the status screen
appears, the status is reported as either out-of-service or in-service, which mean
exactly as stated in the above list, or disconnect, which means the station is in
the ready-for-service state.
exactly as stated in the above list, or disconnect, which means the station is in
the ready-for-service state.
Hardware Error Log Entries and Test to Clear
Values
Values
Notes:
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the appropriate
test description and follow the recommended procedures.
test description and follow the recommended procedures.
2.
Major or Minor alarms on this MO may be downgraded to Warning alarms based on the values used in
the
the
set options
command.
Table 10-224.
Hybrid Line Error Log Entries
Error
Type
Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
0
1
0
Any
Any
Any
test port PCSSpp sh r 1
1 (a)
Any
None
WARNING
OFF
15 (b)
Any
Hybrid Audits Test
(#61)
(#61)
18 (c)
0
busyout port
PCSSpp
PCSSpp
WARNING
OFF
release port PCSSpp
130 (d)
None
WARNING
ON
test port PCSSpp sh
257 (e)
40988
None
MIN/WRN
2
OFF
513 (f)
40965
Hybrid Line Audits
Test (#61)
Test (#61)
WARNING
OFF
test port PCSSpp sh r 4
769 (g)
Remote Dig Loop
Around Test (#59)
Around Test (#59)
WARNING
OFF
test port PCSSpp sh r 3
1025
Hybrid & Conf.
Circuits Test (#57)
Circuits Test (#57)
MIN/WRN
2
ON
test port PCSSpp l r 3
1281 (h)
Local Digital Loop
Around Test (#58)
Around Test (#58)
WARNING
ON
test port PCSSpp l r 3
1537 (i)
40968
None
WARNING
OFF
1793
TDMNPE Crosstalk
Test (#6)
Test (#6)
MIN/WRN
2
ON
test port PCSSpp l r 3
2049 (j)
32770
None
2049 (k)
40967
None
Continued on next page